home *** CD-ROM | disk | FTP | other *** search
/ The Best of Select: Games Special 4 / THE BEST OF SELECT Games Special 4 (Select CD-ROM)(1996).iso / dosgames / oakflat / oakflat.hlp < prev    next >
Text File  |  1991-08-04  |  21KB  |  389 lines

  1.  
  2.                  --<<< SIMULATOR COMMAND SUMMARY LIST >>>--
  3.  
  4.         A                        INSPECTION              SOUND OFF
  5.         ACCIDENT                 MANUAL                  SRCP ON
  6.         ALARM TEST               PRCP ON                 SRCP OFF
  7.         AUTO                     PRCP OFF                SPEED n
  8.         AUTO SHUTDOWN            PPRV OPEN               SPRV OPEN
  9.         COLOR                    PPRV CLOSED             SPRV CLOSED
  10.         DAMAGE                   PRETEST                 TARGET
  11.         DAMAGE CONTROL ON        QUIT                    TOWER PUMP ON
  12.         DAMAGE CONTROL OFF       REFUEL                  TOWER PUMP OFF
  13.         DELAY n                  REPAIRS                 TURBINE TRIP
  14.         DEMAND ON                RESTART                 V
  15.         DEMAND OFF               RESTORE                 VALUE
  16.         DEMO                     RUN UNTIL n             VALVE 1 OPEN
  17.         DOCS                     SAVE                    VALVE 1 CLOSED
  18.         DOCUMENTATION            SCRAM                   VALVE 2 OPEN
  19.         EXIT                     SHIELD ON               VALVE 2 CLOSED
  20.         I                        SHIELD OFF              VIEW ON
  21.                                  SOUND ON                VIEW OFF
  22.  
  23.            All of these commands may be entered by pressing <F7> 
  24.                   and typing the command at the prompt.
  25.  
  26.  
  27.  
  28.                --<<< SIMULATOR COMMAND QUICK HELP LIST >>>--
  29.  
  30.    A = AUTO START Command.
  31.    ACCIDENT = Simulates a sudden loss-of-coolant accident.
  32.    ALARM TEST = Tests all of the audible alarms if SOUND is active. 
  33.    AUTO = Activates Automatic Control Mode.
  34.    AUTO OFF = Initiates an Automatic Shutdown and then ends the simulation.
  35.    AUTO SHUTDOWN = Initiates an Automatic Shutdown then repairs/refueling.
  36.    COLOR = Optimizes the simulators display for a color monitor.
  37.    DAMAGE = Sets the quality of PCS and SCS to POOR (results in damage).
  38.    DAMAGE CONTROL ON = Activates automatic Damage Control Computer.
  39.    DAMAGE CONTROL OFF = De-activates automatic Damage Control Computer.
  40.    DELAY n = Activates a n second pause after each simulated hour (n = 1 - 60).
  41.    DEMAND ON = Activates Varying Demanded Power levels option.
  42.    DEMAND OFF = De-activates Varying Demanded Power Level option.
  43.    DEMO = Activates the interactive Demo Mode.
  44.    DOCS = View DOCUMENTATION using HYPERhelp.
  45.    DOCUMENTATION = View DOCUMENTATION using HYPERhelp.
  46.    EXIT = Quit the simulation immediately to DOS.
  47.    I = INSPECTION command.
  48.    INSPECTION = Reports the last NRC inspection of PCS and SCS.
  49.    MANUAL = De-activates Automatic adjustment of temp/power control settings.
  50.    MONO = Optimizes the simulators display for a monochrome monitor.
  51.    PRCP ON = Turns on the Primary Reserve Coolant Pump.
  52.    PRCP OFF = Turns off the Primary Reserve Coolant Pump.
  53.    PPRV OPEN = Opens the Primary Pressure Release Valve.
  54.    PPRV CLOSED = Closes the Primary Pressure Release Valve.
  55.    PRETEST = Tests all simulated reactor components prior to starting.
  56.    QUIT = Quits the simulation displaying your final score.
  57.    REFUEL = Replaces the reactors fuel rods to 100%.
  58.    REPAIR = Does a complete repair job on all systems having any damage.
  59.    RESTART = Restarts the simulator and resets all settings.
  60.    RUN UNTIL n = Run the simulator until the n day is reached (n = 1 - 2000).
  61.    SCRAM = Immediately takes the reactor off-line in an emergency.
  62.    SHIELD ON = Activates an anti-neutron radiation shield, lowers radiation.
  63.    SHIELD OFF = Turns off the SHIELD option.
  64.    SPEED n = Sets the calculate to view ratio for simulated hours (n = 1 - 24).
  65.    SOUND ON = Activates the SOUND option.
  66.    SOUND OFF = De-activates the SOUND option.
  67.    SPRV OPEN = Opens the Secondary Pressure Release Valve.
  68.    SPRV CLOSED = Closes the SPRV if the valve is open.
  69.    SRCP ON = turns on the Secondary Reserve Coolant Pump.
  70.    SRCP OFF = Turns off the Secondary Reserve Coolant Pump.
  71.    TARGET = Allows for manual setting of Demanded Power level.
  72.    TOWER PUMP ON = Turns on the Cooling Tower Pumps.
  73.    TOWER PUMP OFF = Turns off the Cooling Tower Pumps.
  74.    TURBINE TRIP = By-passes the Steam Turbines in emergency.
  75.    V = Value command.
  76.    VALUE = Displays the current value of the power generated by the plant.
  77.    VALVE 1 OPEN = By-passes Steam Turbine Group #1 in emergency.
  78.    VALVE 1 CLOSED = Closes the by-pass valves for Turbine Group #1.
  79.    VALVE 2 OPEN = By-passes Steam Turbine Group #2 in emergency.
  80.    VALVE 2 CLOSED = Closes the by-pass valves for Turbine Group #12
  81.    VIEW ON = Activates automatically changing view screens.
  82.    VIEW OFF = De-activates automatically changing view screens.
  83.  
  84.  
  85.  
  86.                  --<<< SIMULATOR COMMAND DETAIL LIST >>>--
  87.  
  88.    (A description of the available commands at the <F7> Command Prompt)
  89.  
  90.   A = AUTO START Command.
  91.  
  92.   ACCIDENT = Simulates a sudden loss of coolant accident where there is a
  93.           profound loss of coolant.  For the purpose of the simulator,
  94.           a rapid loss of coolant accident could empty the primary coolant loop
  95.           of all coolant in less than 20 hours.  Counter measures to replace
  96.           the coolant and stop the leak could slow, or even stop a meltdown.
  97.           Once this command is entered it can not be aborted.  If the option
  98.           creates a reactor core meltdown the simulation run is ended.  Only
  99.           use this option to see how devastating such an accident could be,
  100.           and to practice emergency procedures for such an event.
  101.  
  102.    ALARM TEST = Sounds the hourly temperature change alarm, the attention 
  103.           alarm, the warning alarm, and the emergency alarm to test the audio 
  104.           system in the computer.  If the sound is turned OFF no alarms will
  105.           be heard during the test.  Use the SOUND command to turn the 
  106.           speaker back ON.
  107.  
  108.    AUTO = Automatically adjusts the simulators control settings to maintain 
  109.           the power output at or near 100%. MANUAL reverses the command.  
  110.           Controlled by the Auto Adjustment computer, AUTO will adjust CONTROL
  111.           RODS, PCP, SCP, and ECP to maintain a consistent output, and will 
  112.           automatically repair major plant damage (Damage > 25%) and refuel 
  113.           the reactor when needed (Using the AUTO SHUTDOWN command).  It will 
  114.           not maintain coolant levels with the PRIMARY and SECONDARY RESERVE 
  115.           COOLANT PUMP.
  116.  
  117.    AUTO OFF = Initiates the Automatic ShutDown Procedures which will
  118.           set the CONTROL RODS = 0 and turn off the RESERVE COOLANT PUMPS
  119.           if they are activated.  This procedure is activated automatically
  120.           while in the AUTO mode and the FUEL REMAINING < 11 or the TOTAL
  121.           DAMAGE > 24%.  Once the reactor is shutdown the simulation will
  122.           automatically end and your performance will be evaluated.
  123.  
  124.    AUTO SHUTDOWN = Initiates the Automatic ShutDown Procedures which will
  125.           set the CONTROL RODS = 0 and turn off the RESERVE COOLANT PUMPS
  126.           if they are activated.  This procedure is activated automatically
  127.           while in the AUTO mode and the FUEL REMAINING < 11 or the TOTAL
  128.           DAMAGE > 24%.  When the reactor is shutdown, repairs and/or refueling
  129.           procedures will be initiated if the simulator is in AUTO or DEMO mode.
  130.  
  131.    AUTO START = Starts the simulator in AUTO mode, but in addition to the
  132.            normal settings, the DOUBLE option, the DAMAGE CONTROL option,
  133.            and the DEMAND option are all activated.
  134.  
  135.    DAMAGE = Sets the Quality of the workmanship of both the Primary and 
  136.           Secondary Coolant Systems to POOR.  The effect of this is to create 
  137.           substantial amounts of damage to the plant.
  138.  
  139.    DAMAGE CONTROL ON = Instructs the computer to initiate Damage Control 
  140.           automatically on any significant damage found in the plant.  The
  141.           equivalent manual command would be the <F8> function.  The automatic
  142.           system activates emergency repairs when an individual systems 
  143.           damage exceeds 6%.  If the